Authorized Distributor in Egypt
Volvo Penta Diesel Generators in Egypt
Sweden · 85 KVA – 700 KVA
Swedish precision meets extreme-duty performance. Renowned for rapid load acceptance and minimal transient response — the preferred choice for data centers and critical infrastructure.
13 models · 100–700 kVA
Model Range
| Model | Engine | Alternator | Prime kVA | Standby kVA |
|---|---|---|---|---|
| G100VL | TAD531GE | TAL044D | 100.0 | 110.0 |
| G130VL | TAD532GE | TAL044H | 130.0 | 143.0 |
| G150VL | TAD731GE | TAL044J | 150.0 | 165.0 |
| G200VL | TAD733GE | TAL044M | 200.0 | 220.0 |
| G250VL | TAD734GE | TAL046D | 250.0 | 275.0 |
| G300VL | TAD1341GE | TAL046F | 300.0 | 330.0 |
| G350VL | TAD1342GE | TAL046H | 350.0 | 385.0 |
| G400VL | TAD1343GE | TAL0473A | 400.0 | 440.0 |
| G450VL | TAD1345GE | TAL0473B | 455.0 | 500.0 |
| G500VL | TAD1641GE | TAL0473C | 500.0 | 550.0 |
| G600VL | TWD1643GE | TAL0473E | 600.0 | 660.0 |
| G650VL | TWD1644GE | TAL0473F | 650.0 | 715.0 |
| G700VL | TWD1645GE | TAL049B | 700.0 | 770.0 |
The table lists the main models. Ratings from 85 to 700 kVA are available; models outside the table are supplied to order.
Ratings at 50 Hz, 400/230 V, 0.8 power factor. Prime (PRP) is continuous supply at variable load for unlimited hours, with 10% overload available for one hour in every twelve. Standby (ESP) covers the duration of a utility outage and permits no overload.
Most Requested
- G300VLTAD1341GE300.0 kVA
- G350VLTAD1342GE350.0 kVA
Why Volvo Penta
Fully electronic EMS 2.0 engine management, with turbocharging and an intercooler across the range. Volvo Penta genset engines comply with ISO 8528 class G3, the strictest load-acceptance class in the standard: the set reaches stable voltage and frequency faster after the mains drop. That recovery time is what makes this the range to specify for data centres, hospitals and any load that will not tolerate a long transient.
Technical Specifications
Supplied With Every Set
Common Questions
What is the difference between the Prime and Standby ratings?
Prime (PRP) is continuous supply at variable load for unlimited hours, with a 10% overload available for one hour in every twelve. Standby (ESP) covers only the duration of a utility outage and permits no overload. Both figures are listed against every model in the table above.
Which engines are used across the Volvo Penta range?
The range is built on these Volvo Penta engines: TAD531GE, TAD532GE, TAD731GE, TAD733GE, TAD734GE, TAD1341GE, TAD1342GE, TAD1343GE, TAD1345GE, TAD1641GE, TWD1643GE, TWD1644GE, TWD1645GE. Each one is listed against the rating it drives in the table above.
Which alternator is fitted?
LeroySomer / Stamford, with Class H — IP23 insulation and Brushless / PMG excitation.
Which control panel is supplied?
DSE 7320 / ComAp InteliGen. The panel is configured for the application, whether that is a single set, an automatic transfer scheme or a synchronised installation.