The industry benchmark for reliability and fuel efficiency. Engineered for every climate and load profile — from residential backup to heavy industrial prime power.

18 models · 20–1000 kVA

Model Range

ModelEngineAlternatorPrime kVAStandby kVA
G20PL404A-22G1TAL040F20.021.0
G30PL1103A-33GTAL042C30.033.0
G45PL1103A-33TG1TAL042F45.048.0
G60PL1103A-33TG2TAL042H60.064.0
G100PL1104C-44TAG2TAL044D100.0106.0
G150PL1106A-70TAG2TAL044J150.0159.0
G200PL1106A-70TAG4TAL044M200.0212.0
G250PL1506A-E88TAG3TAL046D248.0265.0
G355PL2206A-E13TAG2TAL046H356.0387.0
G400PL2206A-E13TAG3TAL0473A407.0435.0
G500PL2506A-E15TAG2TAL0473C500.0530.0
G600PL2806A-E18TAG1ATAL0473E600.0635.0
G695PL2806A-E18TTAG4TAL049B696.0767.0
G740PL4006-23TAG2ATAL049C743.0816.0
G760PL2806A-E18TTAG5TAL049C759.0838.0
G800PL4006-23TAG3ATAL049C798.0870.0
G900PL4008TAG1ATAL049D905.0965.0
G1000PL4008TAG2ATAL049E1000.01060.0

The table lists the main models. Ratings from 9 to 2500 kVA are available; models outside the table are supplied to order.

Ratings at 50 Hz, 400/230 V, 0.8 power factor. Prime (PRP) is continuous supply at variable load for unlimited hours, with 10% overload available for one hour in every twelve. Standby (ESP) covers the duration of a utility outage and permits no overload.

Most Requested

Why Perkins

The widest span in our catalogue: 18 standard models from 20 to 1000 kVA, with ratings either side supplied to order. Perkins is also offered with a mechanical or an electronic governor. A mechanical set runs without an engine control unit, which means it can be serviced in the field with ordinary tools and is less sensitive to fuel quality — a real advantage on sites far from a service centre. Perkins ElectropaK engines with electronic governing conform to ISO 8528-5 class G3, and the larger models to class G2.

Technical Specifications

Cylinders3 – 16 In-Line / V-Type
GovernorMechanical / Electronic
AspirationTurbocharged
CoolingWater Cooled
EmissionsStage II / IIIA
AlternatorLeroySomer / Stamford
InsulationClass H — IP23
ExcitationBrushless / PMG
ControlDSE 6110 / 7320 / ComAp

Supplied With Every Set

Common Questions

What is the difference between the Prime and Standby ratings?

Prime (PRP) is continuous supply at variable load for unlimited hours, with a 10% overload available for one hour in every twelve. Standby (ESP) covers only the duration of a utility outage and permits no overload. Both figures are listed against every model in the table above.

Which engines are used across the Perkins range?

The range is built on these Perkins engines: 404A-22G1, 1103A-33G, 1103A-33TG1, 1103A-33TG2, 1104C-44TAG2, 1106A-70TAG2, 1106A-70TAG4, 1506A-E88TAG3, 2206A-E13TAG2, 2206A-E13TAG3, 2506A-E15TAG2, 2806A-E18TAG1A, 2806A-E18TTAG4, 4006-23TAG2A, 2806A-E18TTAG5, 4006-23TAG3A, 4008TAG1A, 4008TAG2A. Each one is listed against the rating it drives in the table above.

Which alternator is fitted?

LeroySomer / Stamford, with Class H — IP23 insulation and Brushless / PMG excitation.

Which control panel is supplied?

DSE 6110 / 7320 / ComAp. The panel is configured for the application, whether that is a single set, an automatic transfer scheme or a synchronised installation.